AquaGuidance AGCT-1000 safe drinking water countertop system is the popular choice for people who want ease of install and easy access to their drinking water filter. It is an ideal solution for people that rent and cannot install permanent fixtures to the current plumbing or for college students, business people, or our service men & women that move frequently.
The AGCT-1000 attaches to the existing sink faucet and with a simple push of the diverter valve clean, safe, great tasting drinking water is delivered to the system for your enjoyment. In the original position the valve allows unfiltered water to run directly into the sink to rinse dishes, etc.
– 1750 Gallons Capacity for Lead, Mercury, Chloramine, and Chlorine reduction performance.
– Over 4.75 gallons every day for a year!
This system has been tested according to NSF/ANSI 53 & 42 for the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentrationless than or equal to the permissable limit for water leaving the system as specified by NSF/ANSI 53 & 42.
Substance | Influent Challenge Concentration mg/L | Maximum permissible product water concentration mg/L | Calculated Minimum permissible concentration in % removal3 | AGCT-1000 % removal throughout lifetime of the cartridge |
---|---|---|---|---|
Chloramine taste & odor1 | 3.0 +/- 10% | 0.5 | 83.30% | >99% |
Chlorine taste & odor2 | 2.0 +/- 10% | > or = 50% | 50% | >99% |
Lead pH 6.5 | 0.15 +/- 10% | 0.01 | 93.30% | >98.4% |
Lead pH 8.5 | 0.15 +/- 10% | 0.01 | 93.30% | >98.4% |
Mercury pH 6.5 | 0.006 +/- 10% | 0.002 | 66.70% | >90.9% |
Mercury pH 8.5 | 0.006 +/- 10% | 0.002 | 66.70% | >90.9% |
Chloramine taste & odor1 | |
---|---|
Influent Challenge Concentration mg/L | 3.0 +/- 10% |
Maximum permissible product water concentration mg/L | 0.5 |
Calculated Minimum permissible concentration in % removal3 | 83.30% |
AGCT-1000 % removal throughout lifetime of the cartridge | >99% |
Chlorine taste & odor2 | |
---|---|
Influent Challenge Concentration mg/L | 2.0 +/- 10% |
Maximum permissible product water concentration mg/L | > or = 50% |
Calculated Minimum permissible concentration in % removal3 | 50% |
AGCT-1000 % removal throughout lifetime of the cartridge | >99% |
Lead pH 6.5 | |
---|---|
Influent Challenge Concentration mg/L | 0.15 +/- 10% |
Maximum permissible product water concentration mg/L | 0.01 |
Calculated Minimum permissible concentration in % removal3 | 93.30% |
AGCT-1000 % removal throughout lifetime of the cartridge | >98.4% |
Lead pH 8.5 | |
---|---|
Influent Challenge Concentration mg/L | 0.15 +/- 10% |
Maximum permissible product water concentration mg/L | 0.01 |
Calculated Minimum permissible concentration in % removal3 | 93.30% |
AGCT-1000 % removal throughout lifetime of the cartridge | >98.4% |
Mercury pH 6.5 | |
---|---|
Influent Challenge Concentration mg/L | 0.006 +/- 10% |
Maximum permissible product water concentration mg/L | 0.002 |
Calculated Minimum permissible concentration in % removal3 | 66.70% |
AGCT-1000 % removal throughout lifetime of the cartridge | >90.9% |
Mercury pH 8.5 | |
---|---|
Influent Challenge Concentration mg/L | 0.006 +/- 10% |
Maximum permissible product water concentration mg/L | 0.002 |
Calculated Minimum permissible concentration in % removal3 | 66.70% |
AGCT-1000 % removal throughout lifetime of the cartridge | >90.9% |
1 As monochloramine (measured as Cl2/L)
2 Chloramine testing was used as the surrogate for chlorine reduction.
3 Calculated minimum reduction is determined by using the target influent minus the max allowable concentration divided by the target influent.
PART No. | Unit Dimensions | Lead Mercury Capacity @ Flow4 | Chloramine, Chlorine Capacity @ Flow5 |
---|---|---|---|
AGCT- 1000 | 5”D x 6”W x 12”H | 1750 gal. @ 0.5 GPM 6624 L @ 1.89 LPM |
1750 gal @ 0.5 GPM 6624 L @ 1.89 LPM |
AGCT-1000 | |
---|---|
Unit Dimensions | 5”D x 6”W x 12”H |
Lead Mercury Capacity @ Flow4 | 1750 gal. @ 0.5 GPM 6624 L @ 1.89 LPM |
Chloramine, Chlorine Capacity @ Flow5 | 1750 gal @ 0.5 GPM 6624 L @ 1.89 LPM |
4,5 Certified by IAPMO R&T (International Association of Plumbing and Mechanical Officials) to NSF/ANSI 53 for Lead and Mercury reduction and NSF/ANSI 42 for Chloramine, Chlorine, taste and odor reduction.
(BOTH OUT TO 1750 GALLONS)
PART No. | OD x ID x Length | Lead, MercuryCapacity @ Flow1 | Chloramine, ChlorineCapacity @ Flow1 | Initial PSID@ Flow |
---|---|---|---|---|
APB-0-G-937-F | 2.6” x 1.25” x 9.37”(66mm x 32mmx 238mm) | 1750 gal. @ 0.5 GPM 6624 L @ 1.89 LPM |
1750 gal @ 0.5 GPM 6624 L @ 1.89 LPM |
7 PSID @0.5 GPM |
APB-0-G-937-F | ||
---|---|---|
OD x ID x Length | 2.6” x 1.25” x 9.37”(66mm x 32mmx 238mm) | |
Lead, MercuryCapacity @ Flow1 | 1750 gal. @ 0.5 GPM 6624 L @ 1.89 LPM |
|
Chloramine, ChlorineCapacity @ Flow1 | 1750 gal @ 0.5 GPM 6624 L @ 1.89 LPM |
|
Initial PSID@ Flow | 7 PSID @0.5 GPM |
1Certified by IAPMO R&T (International Association of Plumbing and Mechanical Officials) to NSF/ANSI 53 for Lead and Mercury reduction and NSF/ANSI 42for Chloramine, Chlorine, Taste and Odor reduction when used in the AGCT-1000.
WARNINGS:
Operating Temperature: Range: 33 deg F to 100 deg F
Maximum Operating Pressure: 100 psig/ 8.28bar.
The AGCT-1000 unit and APB-O-G-937F AquaGuidance filter block is designed to be used only on microbiologically safe and adequately disinfected water supplies as it is not designed to kill or remove bacteria or viruses. All test data is certified but performance of the filter may be altered by the source water’s organic content, turbidity, pH, or other conditions encountered in actual use. APB-O-G-937-F is the direct factory replacement cartridge used in the AGCT-1000 CT system and should be flushed a minimum of 20 minutes prior to use.
All performance claims presented here are based on data believed to be reliable but are not to be considered a warranty of performance.
Limited Liability
Seller makes no warranties of any kind, expressed or implied, and expressly disclaims all warranties of every kind, concerning this product, including warranties of merchantability or fitness for a particular purpose, except that this product should be capable of performing as described in this product data sheet. Seller’s obligation shall be limited solely to the refund of the purchase price or replacement of the product, if proven defective, at Seller’s sole discretion. Determination of suitability of product for uses and applications contemplated by Buyer shall be the sole responsibility of Buyer. Use of this product constitutes Buyer’s acceptance of this Limited Liability.
* Comparison of ALL certified standard 10-inch residential filter cartridges.
Installation and Warranty Documents
AGCT-1000 Installation Instruction Sheet AGCT-1000 Spanish Installation Instruction Sheet